Analysis of the Acidity of Olive Oil

CDR OxiTester: the fast, simple and reliable olive oil testing system, to be used directly at theoil mill, in the oil processing plant or at the time of purchaseWith the method devised by the CDR laboratories, it is possible to easily analyze the acidity of olive oil and extra virgin olive oil in 1 minute, along the production line of an oil mill, upon acceptance or during the sales phase. The CDR method simplifies and speeds up the official procedure and the results are aligned to the ISO/AOCS reference method.

Analyzers to test Acidity (FFA) in Olive Oil 

You can determine the percentage of acidity of olive oil with the CDR OxiTester, a tool for the analysis of olive oil of the CDR FoodLab® line available in 2 versions, CDR OxiTester and CDR OxiTester Junior.

  CDR OxiTester per analisi su olio di oliva
CDR OXITESTER

CDR OxiTester  Junior per analisi su olio di oliva
CDR OXITESTER
JUNIOR
Parameters Olive Oil:

Acidity (FFA)
Peroxide Value
Total Polyphenols/OSI
K270

Olive Oil:

Acidity (FFA)
Peroxide Value
Total Polyphenols/OSI  (optional)

Simultaneous Sample Analyses 16 3
Multiple Analyses on a Sample si

Method

End point test.
Test time: 1 minute.
It is possible to perform several test sessions with a maximum of 16 samples.

Principle of the test

The fatty acids of the sample, under conditions of pH <7.0, react with a chromogen, developing a color whose optical density, measured at 630 nm, is proportional to the concentration of the fatty acid, expressed as % of oleic acid.

Correlation Curve

The correlation curve of the CDR OxiTester analytical method with the AOCS Official Method Ca 5a-40 of reference

Comparison between the OxiTester method of analysis of the acidity of olive oil and the ISO/AOCS reference method

 

Reagent test Kits

The reagents are packaged in foil pouches containing 10 tubes useful to perform 10 analyses.

This is the minimum package that allows the use of CDR systems even to those who need to make a few analyses, thus not wasting reagents.

There are also boxes of 100 tests, however, packaged in 10 bags of 10 tubes containing the reagent.

Code *300128/A: 10 test.

Code *300125/A: 100 test (10 buste da 10 test)

For samples, with high acidity, where a dilution is requested, you must use an appropriate reagent kits.

Code. 300129: 100 tests.

The reagents have a shelf-life of 12 months.

Sample handling and usage of curves

Sample
Oil: collect as is 

Measuring range Code Resolution  ResolutionRepeatability
0,03 – 1,1% oleicAc. *300128/A
*300125/A
0,01% oleicAc. 0,02% oleicAc.
1 – 3,5% oleicAc. *300128/A
*300125/A
0,01% oleicAc. 0,1% oleicAc.
1 – 13% oleicAc. *300128/A 
*300125/A
0,01% oleicAc. 0,5% oleicAc.

Reagents developed by CDR S.r.l - Quality System Certified ISO 9001 Ed. 2015 - Certificate n. 9115

Take a Look at CDR OxiTester olive oil testing in few minutes easy to use, compliance with AOCS methods

Acidity (FFA) was last modified: March 6th, 2019 by CDR s.r.l.