Determination of L-Lactic Acid on silage and animal feed
The determination of lactic acid in silage and animal feed is important because it provides essential information on hygienic quality, preservation processes, and the nutritional value of the product. This parameter is particularly relevant for fermented feeds and silages, but it is also useful for the evaluation of compound feeds and by-products. The presence of lactic acid is directly related to the activity of lactic acid bacteria, which convert fermentable sugars into lactic acid, leading to a reduction in feed pH. An adequate lactic acid content is generally indicative of proper fermentation, especially in silages, as the pH decrease helps inhibit the growth of undesirable microorganisms such as molds, yeasts, and pathogenic bacteria, thereby improving feed stability and shelf life.
Method
Test type: End Point.
Testing time: 7 minutes.
Analysis sessions with multiple samples are possible up to a maximum of 16 tests for CDR FoodLab® and 3 tests for CDR FoodLab® Junior.
...
Sample treatment
Weigh 1 g of sample and add 10 mL of 0.25 N NaOH. Shake using a Stomacher or a magnetic stirrer for at least 3 minutes. If necessary, filter using a filtration kit (code 300210). Opalescence does not interfere with the reaction.
Principle of the test
L-Lactic acid is oxidized to pyruvate by an enzymatic reaction that produces H2O2. H2O2, in the presence of peroxidase and a phenolic derivate, forms a colored complex whose intensity was read at 545nm and is directly proportional to the concentration of L-lactic acid in the sample.
Calibration curve
The calibration curve of the CDR FoodLab® system confirmed excellent linearity across the entire measurement range.
...
Reagent test Kits
Measuring range
| Analyses | Measuring range | Resolution | Repeatability |
|---|---|---|---|
| Lactic acid - silage | 100 - 8000 ppm | 1 ppm | 92 ppm |
The analyzers for oils and fats quality control
CDR FoodLab®
Complete analysis panel, supplied already configured
Up to 16 determinations simultaneously
Possibility of carrying out analyses of the same sample
Integrated printer
Full connections (LAN - USB - Bluetooth barcode/QR code reader)
CDR FoodLab® Jr
Partial analysis panel, customisable configuration
Up to 3 determinations simultaneously
Wireless connection to external printer